Diagnose · Reference TL-004 · Technical review:

Your Battery Sags Under Load. Where Is the Voltage Lost?

Separate cell behavior from losses in joints, switches and cables using synchronized measurements at defined electrical boundaries.

Start with the decision ↓

The engineering decision

Measure the cell stack and equipment terminals during the same event. Then subdivide the difference until the dominant loss is located.

Have these inputs ready

  • Synchronized load current and voltages
  • Measurement points and return path
  • SOC, temperature and event duration
  • Controller and BMS event logs

Follow the voltage to the equipment

Scroll horizontally to view the full diagram →

Follow the voltage to the equipmentHypothetical 100 A measurement: 1.2 V of cell-stack sag plus 0.8 V of external-path drop. Before step, zero-current baseline 52.0 V; Loaded stack 50.8 V; Pack output 50.5 V; Equipment 50.0 V52.0 VBefore step50.8 VLoaded stack50.5 VPack output50.0 VEquipmentVoltage profile · 100 A
Hypothetical 100 A measurement: 1.2 V of cell-stack sag plus 0.8 V of external-path drop.

Define the measurement boundaries

The open-circuit to loaded cell-stack change includes cell dynamics. The loaded stack-to-equipment difference is the loss across the intervening conductors and components. These quantities must be captured at the same current and time; comparing a rested voltage with a later BMS display can mix several different effects.

Measure both outgoing and return conductors. A ground-reference shift can reset electronics even when the battery remains above its nominal cutoff. Use appropriately rated differential or isolated instruments for the circuit; an earth-referenced oscilloscope ground can short a floating battery node.

ΔVexternal = Vstack,loaded − Vequipment Rsegment ≈ ΔVsegment / I

Turn millivolts into a loss budget

At a hypothetical steady 100 A, a 0.30 V drop between the loaded stack and pack output implies 3 mΩ in that segment. Another 0.50 V between the output and equipment implies 5 mΩ in the cable and mating path. The external path dissipates about 80 W in total.

The stack itself falls from 52.0 V at a zero-current baseline before the step to 50.8 V at the selected sample time. Dividing this 1.2 V by the current step gives an apparent 12 mΩ pulse resistance. Record that sample time: polarization means a later sample can give a different result.

Hypothetical synchronized 100 A measurementsScroll horizontally to compare all columns →
BoundaryDropApparent resistancePower loss
Cell stack, before/after current step1.20 V12 mΩ at stated timeDynamic cell estimate
Loaded stack → pack output0.30 V3 mΩ30 W
Pack output → equipment0.50 V5 mΩ50 W

Choose the next branch from the evidence

Diagnostic branchesScroll horizontally to compare all columns →
ObservationNext measurementLikely investigation
All groups sag similarlyRepeat at controlled SOC and temperatureCell capability, aging or excessive load
One group is an outlierGroup voltage plus independent verificationMismatch, joint or sense connection
Stack stable; equipment voltage fallsDrop across each series segmentFuse, switch, connector, cable
Reported sag without independent sagSense lead routing and sample timingMeasurement artifact
Voltage recovers after disconnectFault log captured before recoveryProtection trigger and load profile

Keep the test reproducible

Use separate force and sense connections where possible. Place the sense points on the actual terminals of the segment being evaluated. Record current-probe offset, instrument range and sampling bandwidth. A slow logger can miss the minimum voltage of a short acceleration event.

Begin with a repeatable load step within the approved operating limits. Stop on an abnormal temperature rise, damaged connection or protection event. Repeat at the required service corners only after the first anomaly has been resolved.

Compare the repaired path with the original trace at the same SOC, temperature and load. A lower contact drop that simply moves the limiting condition into the cells is not a completed system validation.

Measurement & validation procedure

Application acceptance checklistScroll horizontally to compare all columns →
Test / reviewRecordAcceptance condition
Capture the eventStack V, equipment V, current and timestampTraces share a time base and resolve the shortest event
Subdivide external lossesMillivolts across each segment and returnSum agrees with stack-to-equipment difference within uncertainty
Verify corrective actionBefore/after trace at matched conditionsEquipment voltage and temperature remain within limits

Continue this engineering task

Related engineering guidance

Prepare the evidence for review

  • Annotated measurement-point diagram
  • Synchronized voltage/current capture
  • SOC, temperatures and pulse duration
  • Fault log before reset
Continue to engineering review

Technical sources & claim support

References support the stated engineering principles. Worked examples use their explicitly stated assumptions.

  1. Keysight: How to Test Coin Cell Batteries ↗

    Coin Cell Battery Testing and Modeling: four-wire sensing, pulse resistance, pulse width/rest time and defined cutoffs

    Measurement principles illustrated with coin cells. Select the current profile, fixture, sampling, temperature and cutoff conditions for the actual cell or pack.

  2. Texas Instruments BQ76952 data sheet, SLUSE13B ↗

    Sections 7 and 10–12: electrical characteristics, measurement, protection and FET control

    Example of a monitor/protector architecture; capabilities depend on the selected IC and complete circuit.

  3. Molicel INR-21700-P45B product data sheet, revision 1.2 ↗

    Cell specifications; discharge-rate and temperature characteristics

    Cell-specific capacity, impedance and rate/temperature data; worked examples state their own input values.

Key claims and evidence
Evidence mappingScroll horizontally to compare all columns →
ClaimBasisReference
Four-wire sensing reduces lead-resistance contributiondocumentationKeysight: How to Test Coin Cell Batteries
The external-path drop can be subdivided at synchronized currentinferencecalculation
0.8 V at 100 A corresponds to 80 Wcalculationcalculation