EVANTEON Battery SystemsRequest a Quote

Design · Reference TL-013 · Technical review:

What Should the BMS Measure and Control?

A BMS is a measurement, protection and control system. Its architecture follows the battery voltage, current path, isolation boundary, charger and equipment interface.

Start with the decision ↓

The engineering decision

Define every measured quantity, control output, fault response and communication boundary before selecting the monitor, controller and switching hardware.

Have these inputs ready

  • Series-cell count and voltage window
  • Continuous, peak and fault current
  • Contactor or FET topology and precharge
  • Temperature locations, isolation boundary and equipment communication

BMS signal and control boundary

Scroll horizontally to view the full diagram →

BMS signal and control boundaryCell and pack measurements feed the controller independently. Commands go to switching hardware and equipment interfaces; these are signal connections. Cell V & T; Pack V & I; BMS logic; Switching; Charger / hostCell V & TPack V & IBMS logicSwitchingCharger / hostMeasurements → controller → commands and status
Cell and pack measurements feed the controller independently. Commands go to switching hardware and equipment interfaces; these are signal connections.

Measure the quantities that define a safe operating decision

Cell voltage and temperature support cell-level limits. Pack current and voltage support state estimation, power limits and current-path diagnosis. High-voltage systems may also require isolation monitoring and precharge-node measurement. ADBMS2950B supports the required voltage measurements with external high-voltage circuitry; the host calculates isolation resistance. A cell-monitor IC alone is not a complete isolation-monitoring system.

A channel count is not an architecture. Specify range, accuracy, timing, synchronization and behavior when a sensor or communications link fails.

Core BMS measurement mapScroll horizontally to compare all columns →
QuantityEngineering useFailure to resolve
Cell voltageOver/undervoltage, balancing, SOC supportWeak group or open sense lead can be missed
Pack currentPower limits, charge integration, fault detectionSOC drift and incorrect protection behavior
TemperatureCharge/discharge limits and thermal diagnosisLimiting hot or cold cells remain invisible
Pack / precharge voltageContactor sequencing and welded-contactor checksUnsafe or unreliable startup
Isolation resistanceHV insulation supervisionInsulation degradation remains undetected

Define the response, not only the threshold

Each BMS protection needs a threshold, delay, recovery rule, event record and resulting action. The equipment must know whether available power is being reduced, charging is inhibited or the battery is opening its current path.

Precharge, contactor feedback, charger enable and equipment communication belong in one state machine. Review startup, normal operation, shutdown, sleep, service and fault recovery as explicit states.

SOC and SOH are estimates built from measurements and a model. Define capacity reference, initialization, current-offset calibration and correction conditions. Charge accumulation alone does not establish SOC. Validate estimated reserve against delivered charge and energy across temperature and aging; keep cell-voltage and temperature protection active independently of the reported SOC.

Control outputs and interfacesScroll horizontally to compare all columns →
FunctionOutputEvidence
Current pathFET or contactor commandsState transition and feedback log
ChargingEnable and current/voltage limitsCharger response at normal and fault states
EquipmentCAN or discrete statusMessage definition, timeout and fallback
ServiceDiagnostic data and event historyTimestamped fault and operating records

Treat the sensing harness as part of the measurement system

Sense-wire routing, connector retention, reference paths and electromagnetic interference affect the result reaching the monitor. Mechanical routing and electrical filtering therefore need a joint review.

Document plausible open-wire, short-to-adjacent-wire and connector-intermittency failures. Validate detection with the production harness and representative switching noise.

Measurement & validation procedure

Application acceptance checklistScroll horizontally to compare all columns →
Test / reviewRecordAcceptance condition
Validate measurement channelsCalibrated cell/pack voltage, current and temperature at range limits; harness and firmware revisionError and response time meet the allocated budget
Exercise transitions and faultsStartup, charge, discharge, sleep, timeout and sensor-fault event logsSwitching, charger and host reach the specified state within the agreed delay
Release the interface definitionI/O list, message timing, threshold/recovery table and diagnostic recordsHardware and firmware reproduce the validated behavior

Continue this engineering task

Related engineering guidance

Prepare the evidence for review

  • BMS input/output list
  • Protection and recovery table
  • State diagram and communications definition
  • Sense-harness drawing and diagnostic plan
Continue to engineering review

Technical sources & claim support

References support the stated engineering principles. Worked examples use their explicitly stated assumptions.

  1. Texas Instruments: Designing high cell count automotive applications with BQ79616-Q1 ↗

    Slides 12, 14–19 and 35–37: high-current and temperature-gradient challenges, wiring and mechanical design, sensing, balancing and system requirements

    System design reference; component limits and architecture must be verified for the selected implementation.

  2. Analog Devices: ADBMS2950B Battery Pack Monitor ↗

    Rev. 0, Figure 46 (page 67): current, high-voltage and temperature measurement circuits; isolation resistance calculated by the host

    Example of pack-level measurements; it does not define a complete BMS architecture by itself.

  3. Analog Devices: Battery Stack Monitor Maximizes Performance of Li-Ion Batteries ↗

    Cell voltage, current and temperature monitoring; wiring, EMI and connector reliability

    Architecture guidance; validation remains specific to the pack, harness and operating environment.

  4. Texas Instruments BQ76952 data sheet, SLUSE13B ↗

    Sections 7 and 10–12: electrical characteristics, measurement, protection and FET control

    Example of a monitor/protector architecture; capabilities depend on the selected IC and complete circuit.

  5. Texas Instruments: Currently Questioning the Accuracy of Your Battery Monitor? Improve Battery Safety and Accuracy with These Tips, SSZT301 ↗

    Gauging discussion; Current ADC measurement; Accumulated charge measurement

    BQ76942/BQ76952 current and accumulated-charge measurements are inputs to gauging algorithms. Current gain and offset calibration affect the accumulated-charge accuracy.

Key claims and evidence
Evidence mappingScroll horizontally to compare all columns →
ClaimBasisReference
ADBMS2950B with external circuitry and host processing supports pack current/voltage, precharge and isolation-resistance assessmentdocumentationAnalog Devices: ADBMS2950B Battery Pack Monitor
Harness routing and connector behavior affect reliable cell monitoringdocumentationTexas Instruments: Designing high cell count automotive applications with BQ79616-Q1; Analog Devices: Battery Stack Monitor Maximizes Performance of Li-Ion Batteries
Charge accumulation must be processed by a gauging algorithm to estimate state of chargedocumentationTexas Instruments: Currently Questioning the Accuracy of Your Battery Monitor? Improve Battery Safety and Accuracy with These Tips, SSZT301
Protection behavior must be defined as a complete state responseworkflowengineering workflow