Why DCIR Depends on Pulse Duration

Calculated DCIR changes with pulse duration because terminal voltage continues to evolve after the current step.

Start with the decision ↓

The engineering decision

Choose and report the DCIR sampling time from the application load, measurement bandwidth and intended physical interpretation.

Have these inputs ready

  • Application peak duration
  • Pulse current and voltage trace
  • Tester rise time and sample rate
  • Cell SOC and temperature

The sampling time changes the reported response

Scroll horizontally to view the full diagram →

The sampling time changes the reported responseIllustrative normalized traces, not test data. Voltage continues changing during a current plateau and recovers after load removal. Current step; Early sample; Later sample; Unload; RecoveryCurrent · schematicVoltage · schematict0: current stepLoad removedVoltage keeps evolvingRelaxation
Illustrative normalized traces, not test data. Voltage continues changing during a current plateau and recovers after load removal.

One pulse produces several time-defined values

Resistance at time t is ΔV(t)/ΔI. At early time, fast conduction and instrument response dominate. At later time, polarization and transport contribute more strongly.

Illustrative values: a 50 A step with a 0.200 V drop at 100 ms gives 4.00 mΩ, while a 0.250 V drop at 1 s gives 5.00 mΩ. These invented values explain the arithmetic; actual results require measured synchronized samples.

R(t) = ΔV(t) / ΔI

References: A study of the influence of measurement timescale on internal resistance characterisation methodologies for lithium-ion cells; Comparison of Several Methods for Determining the Internal Resistance of Lithium Ion Cells

Long pulses move the battery state

A pulse transfers charge according to ΔQ = IΔt. As duration grows, the voltage difference can include movement along the OCV-SOC curve as well as the intended dynamic response.

Pulse heating can also change resistance during the measurement. Preserve current, voltage and temperature traces when the pulse is energetic enough for this to matter.

The shortest timestamp is not automatically best

Sampling too early can measure current-source rise time, fixture inductance, noise or channel misalignment. The timestamp must be late enough for the test system to resolve and early enough for the intended interpretation.

Use the actual duty cycle as the final acceptance test when its pulse sequence is known.

Measurement & validation procedure

Application acceptance checklistScroll horizontally to compare all columns →
Test / reviewRecordAcceptance condition
Resolve the test-system transitionCommanded and measured current plus synchronized voltageDeclared timestamp is outside unresolved rise-time or alignment error
Calculate resistance at stated timesR(t) values with SOC, temperature and pulse directionEvery reported value carries its timestamp and condition
Compare with the duty cyclePredicted and measured minimum loaded voltageSelected pulse time supports the application decision

Continue this engineering task

Related engineering guidance

Prepare the evidence for review

  • Application pulse definition
  • Test-system bandwidth record
  • Time-indexed resistance results
  • Duty-cycle correlation
Continue to engineering review

Technical sources & claim support

References support the stated engineering principles. Worked examples use their explicitly stated assumptions.

  1. A study of the influence of measurement timescale on internal resistance characterisation methodologies for lithium-ion cells ↗

    Scientific Reports 8, 21 (2018); abstract and Figure 7: comparison at matched measurement timescales

    Peer-reviewed cell study. Numerical values apply only to the tested cells, SOC, temperature and equipment.

  2. Comparison of Several Methods for Determining the Internal Resistance of Lithium Ion Cells ↗

    Sections 4–5: DC step, AC resistance, impedance spectroscopy and pulse-duration effects

    Peer-reviewed method comparison. The proposed timing and cell values are not universal acceptance requirements.

Key claims and evidence
Evidence mappingScroll horizontally to compare all columns →
ClaimBasisReference
Calculated resistance increased with pulse duration for the tested cells and conditionsdocumentationA study of the influence of measurement timescale on internal resistance characterisation methodologies for lithium-ion cells; Comparison of Several Methods for Determining the Internal Resistance of Lithium Ion Cells
Long high-current pulses can include voltage change from SOC movementdocumentationComparison of Several Methods for Determining the Internal Resistance of Lithium Ion Cells
The application duty should determine the useful sampling windowworkflowengineering workflow